Double Pole Double Throw (DPDT) Relay.

Pins

COIL1
input
First terminal of the coil
COIL2
input
Second terminal of the coil
P1
contact
First pole
NC1
contact
Normally closed - connected to P1 when coil unpowered
NO1
contact
Normally open - connected to P1 when coil powered
P2
contact
Second pole
NC2
contact
Normally closed - connected to P2 when coil unpowered
NO2
contact
Normally open - connected to P2 when coil powered

Operation

The relay is an electronic switch with two states: coil unpowered, and coil powered. By default, the coil is unpowered. You can power the coil by applying voltage between the pins COIL1 and COIL2. When the coil is unpowered, P1 is connected to NC1, and P2 is connected to NC2 (NC means normally closed/connected). When the coil is powered, P1 is connected to NO1, and P2 is connected to NO2 (NO means normally open/disconnected).